Computer measuring unit used to transmit information from sensors on the CPU,
operates simultaneously with 3 sensors, converting the analog signal to digital.
Computer measurement unit uses the «Plug and play»: automatic detection of data.
Specifications:
Take time measurement of real-time not less than 0.05 sec / 0.005 sec Channel 3 / 1 channel independent mode 0.0001 sec;
Readability is not less than 12 bits;
Digital input / output of at least one channel;
Memory is not less than 1 MB
Communication port for at least 1 USB-channel
Educational software for recording, displaying and analyzing data.
Interactive workbook, allowing data collection and analysis.
Availability of software in the Russian and Kazakh languages.
Sensor measuring an ECG (electrocardiogram)
1. Measures the electrical signals produced by the heart, and makes electrocardiograph
2. Three-wire electrode
3. Powerful sensor modifiable through built-in flash memory
4. Digital signal processing provides accurate, stable and repeatable measurements
5. Diagram of electrode connections, printed in block unification of the signals for quick reference in the laboratory
Specifications:
1) Range: not less than 0 - 5 mV
2) Resolution: no less than 5 μV
3) Pulse: not less than 47 - 250 times per minute
4) Resolution: at least 1 time / min
PH sensor
1. Made of hard plastic and impact-resistant polycarbonate
2. The process of digital signal provides accurate, stable and repeatable measurements
Required specifications:
5) Range: Not less than pH 0 - 14
6) Resolution: at least ± 0,00036 pH
Spirometer
Spirometer can be used to perform various tests related to air flow and lung volume. The sensor is designed to protect and accurate measurement of both air flow and air flow on inspiration.
Carbon dioxide sensor
1. Made of durable, impact-resistant polycarbonate plastic
2. Digital signal processing provides accurate, stable and repeatable measurements
Specifications:
7) Range: 0 - 5.00 ppm (0 - 0.5%)
8) Resolution: 2.44 ppm for at least
9) Accuracy: ± 100rrm (0 - 1.00 ppm); ± 10% (1,000 - 5,000 ppm)
Temperature probe
1. Accurately measures the temperature changes in real time
2. Ideal for small or hard to reach places
Specifications:
10) Range: at least -25 ° C - +125 ° C
11) Resolution: at least ± 0,1 ° C
12) The properties of the probe: Thermistor, Stainless Steel
13) Reading speed: not less than 10
Chemical resistance: not less than 15 minutes.
Sensor "barometer"
Specifications:
14) Range: not less than 0 - 2,068 hPa
15) Resolution: at least 1,69 hPa
Determine the force sensor
1. Contains hook and rubber bumper and the thumbscrew to mount
2. Power probe widens
3. Made of durable, impact-resistant polycarbonate plastic
4. Digital signal processing provides accurate, stable and repeatable measurements
Specifications:
16) Range: ± 10N / ± 80N
17) Resolution: ± 0,0056 / ± 0,056
18) Sensor Type: electric load cell.
Determination of gas sensor
1. Made of durable, impact-resistant polycarbonate plastic
2. Digital signal processing provides accurate, stable and repeatable measurements
Specifications:
19) Range: Not less than -1,000 - 3,000 hPa
20) Resolution: at least 1,3 hPa
21)
Determination of dissolved oxygen sensor
1. Made of durable, impact-resistant polycarbonate plastic
2. Digital signal processing provides accurate, stable and repeatable measurements
Specifications:
1) Range: at least 0 - 15 mg / L
2) Accuracy: ± 0,2 mg / L
3) Resolution: at least 0.007 mg / L
4) Response Time: 95% - 30 sec, 98% - 45 sec
22) Temperature compensation: 5 - 35 ° C.
Determining heart rate sensor
23)
1. Made of durable, impact-resistant polycarbonate plastic
2. Digital signal processing provides accurate, stable and repeatable measurements
Specifications:
24) Range: 0 - 250 times / min
Resolution: at least 1 time / min